Let's take a look at their comparison facts.. and find out the better one among them.....
| 
   
Topic 
 | 
  
   
HVDC 
 | 
  
   
HVAC 
 | 
 
| 
   
Investment cost 
 | 
  
   
lesser 
 | 
  
   
Higher 
 | 
 
| 
   
Conductor Nos. 
 | 
  
   
2/Dc circuit 
 | 
  
   
3conductor/3
  phase 
 | 
 
| 
   
Supporting tower 
 | 
  
   
smaller 
 | 
  
   
Larger 
 | 
 
| 
   
Terminal converter cost 
 | 
  
   
Very High 
 | 
  
   
Not required 
 | 
 
| 
   
Skin losses 
 | 
  
   
Absent 
 | 
  
   
present 
 | 
 
| 
   
Controllability 
 | 
  
   
HVDC offers
  greater controllability due to lack of inductance, power can be controlled 
 | 
  
   
Lesser than
  HVDC,power can’t be controlled 
 | 
 
| 
   
Interference with nearby communication lines 
 | 
  
   
Chances
  are lower 
 | 
  
   
Chances
  are higher, due to strong magnetic field. 
 | 
 
| 
   
Short circuit current rating 
 | 
  
   
Receiving Current
  in HVDC is low 
 | 
  
   
Receiving Current
  in HVAC is Higher, Circuit breaker needed of higher rating to provide safety 
 | 
 
| 
   
Asyschronous Interconnection 
 | 
  
   
Possible 
 | 
  
   
Impossible
  due to various range of frequency and it’s fluctuations 
 | 
 
| 
   
Voltage Regulation 
 | 
  
   
Higher than
  HVAC 
 | 
  
   
Lower Than
  HVDC 
 | 
 
| 
   
For transmission 
 | 
  
   
HVDC
  is the best suitable 
 | 
  
   
HVAC
  is not the best choice, it has higher losses 
 | 
 
| 
   
For Distribution 
 | 
  
   
HVDC , not
  suitable 
 | 
  
   
HVAC, best
  suitable 
 | 
 
| 
   
Step up/down 
 | 
  
   
Not
  possible, Transformer doesn’t work in DC 
 | 
  
   
Possible
  through the usage of X-former 
 | 
 
| 
   
Frequency Fluctuation 
 | 
  
   
No chance 
 | 
  
   
Bigger chance,
  occurs regularly 
 | 
 
| 
   
Stability in system 
 | 
  
   
Greater
  stability 
 | 
  
   
Lesser
  than HVDC 
 | 
 
| 
   
Line loss comparison 
 | 
  
   
33% lesser
  than ac line 
 | 
  
   
33% higher
  than DC line 
 | 
 
| 
   
Power factor 
 | 
  
   
Always
  unity, as resistive 
 | 
  
   
0.945
  lagging, compensation needed. 
 | 
 
| 
   
Insulators needed 
 | 
  
   
Then, 2/3 of
  AC line 
 | 
  
   
If 1 
 | 
 
| 
   
Power carrying capacity in same tower 
 | 
  
   
1440MVA
  @380KV DC, 300% higher than AC line 
 | 
  
   
480MVA
  @ 220KV AC 
 | 
 
| 
   
Economical and Environmental Advantage 
 | 
  
   
higher 
 | 
  
   
lower 
 | 
 
| 
   
Directionality of link 
 | 
  
   
Bi-polar 
 | 
  
   
Uni-polar 
 | 
 
![]()  | 
| same tower, different power carrying capacity ####So you have found out the best system among them  | 